X-ray phase contrast microtomography system
The Exciscope system is designed for high-resolution phase contrast CT. The main components of an X-ray phase contrast microtomography system are the X-ray source, the motion system that controls the position and rotation of the sample, and the X-ray dete
product description
The Exciscope system is designed for high-resolution phase contrast CT. The main components of an X-ray phase contrast microtomography system are the X-ray source, the motion system that controls the position and rotation of the sample, and the X-ray detector. The Exciscope X-ray Phase Contrast Microtomography System offers a unique combination of contrast, resolution and speed. Thanks to high-performance components, precise scanning algorithms and carefully tailored image reconstruction, fast, high-resolution scanning of low-contrast samples is now possible in a compact design. The image processing software is cloud-based and allows for to a web interface to access data and reconstruction tools. This also allows the use of computationally intensive algorithms.
X-ray phase contrast imaging exploits the principle of slight refraction of X-ray photons as they pass through an object. This enables lower atomic number materials such as biological tissue, food and plastics to have better image contrast.
Absorption Contrast Phase Contrast
To achieve higher quality of phase contrast tomography, phase recovery and specialized artifact handling are necessary. If not handled properly, many types of flaws will appear.
Application direction
①Biomedicine
②Composite material
③Archaeology
④Food Science
⑤Classic Art
Main configuration
①High brightness liquid target X-ray source: MetalJet (optional)
A high-brightness liquid target x-ray source is used, which can operate with short scan times, albeit with the increased distance required for propagation-based imaging. The light source can operate from 20 to 160kV, up to 250 or 1000W, depending on the x-ray source model. Liquid alloys have characteristic line emission at 10keV and 24keV, but the average energy of the emission spectrum can be adjusted by different filters;
②Detector: Tailor-made system
The system implements different detectors, and the resolution and field of view can be selected directly in the acquisition software. For high-resolution imaging, lens-coupled detectors are used, with resolution below 1 µm in 3D. A 7-axis motion system is used to control the position and rotation of the sample, as well as switch between different detectors. The entire assembly is placed on a vibration-damped platform inside a radiation-shielded cabinet.
③Advanced software
To take advantage of phase contrast imaging, all details must be handled correctly. To give researchers more time to focus on specific application directions, we can provide automated custom solutions:
• Easy-to-adjust sample-specific phase search
• Various workpiece reduction techniques
• Detector specific and light source specific calibration
• Fast cone beam tomography reconstruction on GPU
• Coming soon: Iterative reconstruction techniques
X-ray phase contrast imaging system, phase microscopy imaging system, X-ray phase contrast system, phase contrast micro CT imaging system, phase contrast imaging system
因用于机器人各方面应用且与大多数机器人类型兼容,AutoCal系统可以检测出机器人自身构造和工具中心点(TCP)的 突然改变或偏离,并且该系统无需人为干涉就自动地更正这些误差。
AutoCal系统-Dynalog的先进水平校准技术,Dynalog是机器人单元标定技术的世界领导者。它的主流产品DynaCal 系统,被应用于离线的机器人单元校准,并作为最精确的和技术先进的机器人校准程序为许多机器人制造商和终端使用者所接受。AutoCal 系统将已证实的DynaCal校准技术结合到一个在线的全自动系统中,该系统专为程序控制和复原而设计的,价格低廉。
AutoCal系统提供在线的机器人校准方案,旨在快速和自动地保证机械设备的工作性能。因用于机器人各方面应用且与大多数机器人类型兼容,AutoCal系统可以检测出机器人自身构造和工具中心点(TCP)的 突然改变或偏离,并且该系统无需人为干涉就自动地更正这些误差。这意味着不用猜测哪里会出错,不用浪费宝贵时间在机器人程序重复校准上,产品品质无任何损失。